COMMAND to Constant Current Load

The Constant Current Load only supports write commands: It is implemented with a 14-bit DAC and the Board Controller will process the requested current level to achieving the correct current level for the Constant Current Load.

The Board Controller will also monitor the PCB temperature and shut off the Constant Current Load if the PCB temperature is higher than 125°C.

Table 1. Example: Set Constant Current Load to 2450mA
SYNC ADDRESS SENDER COMMAND NBYTES DATA CS CR
U E P C 2 int mA Calc ¬
0x55 0x45 0x50 0x43 0x02 0x0992 0xCA 0x0D