Fault Control

Name:
FAULTCTRL
Offset:
0x12
Reset:
Loaded from fuse
Access:
Configuration Change Protection
Bit76543210
CMPDENCMPCENCMPBENCMPAENCMPDCMPCCMPBCMPA
AccessR/WR/WR/WR/WR/WR/WR/WR/W
Resetxxxxxxxx

Bits 4, 5, 6, 7 – CMPEN: Compare x Enable

Compare x Enable

These bits enable Compare as output on pin. At reset the content is kept and during the reset sequence loaded from the TCD Configuration Fuse (FUSE.TCDFG).

Bits 0, 1, 2, 3 – CMP: Compare Value x

Compare Value x

These bits set the default state from Reset, or when a input Event triggers a Fault causing changes to the output. At reset the content is kept and during the reset sequence loaded from the TCD Configuration Fuse (FUSE.TCDFG).