Device |
The Temperature Sensor is Not Calibrated on Parts with Date Code 727, 728 and 1728 (Year 2017, Week 27/28) |
* |
X |
ADC |
One Extra Measurement Performed After Disabling ADC Free-Running Mode |
* |
X |
ADC Functionality Cannot be Ensured with CLKADC Above 1.5 MHz and a Setting of 25% Duty Cycle |
* |
X |
ADC Performance Degrades with CLKADC Above 1.5 MHz and VDD < 2.7V |
* |
X |
CCL |
Connecting LUTs in Linked Mode Require OUTEN Set to ‘1’ |
* |
X |
D-latch is Not Functional |
* |
X |
RTC |
Any Write to the RTC.CTRLA Register Resets the RTC and PIT Prescaler |
* |
X |
Disabling the RTC Stops the PIT |
* |
X |
TCB |
Minimum Event Duration Must Exceed the Selected Clock Period |
* |
X |
The TCA Restart Command Does Not Force a Restart of TCB |
* |
X |
USART |
TXD Pin Override Not Released When Disabling the Transmitter |
* |
X |
Frame Error on a Previous Message May Cause False Start Bit Detection |
* |
X |