MDCON0

Modulation Control Register 0
Note:
  1. 1.The modulated output frequency can be greater and asynchronous from the clock that updates this register bit, the bit value may not be valid for higher speed modulator or carrier signals.
  2. 2.MDBIT must be selected as the modulation source in the MDSRC register for this operation.
Name:
MDCON0
Offset:
0xF51
Reset:
Access:
Bit76543210
ENOUTOPOLBIT
AccessR/WR/WR/WR/W
Reset0000

Bit 7 – EN: Modulator Module Enable bit

Modulator Module Enable bit

ValueDescription
1

Modulator module is enabled and mixing input signals

0

Modulator module is disabled and has no output

Bit 5 – OUT: Modulator Output bit

Modulator Output bit

Displays the current output value of the modulator module.

Bit 4 – OPOL: Modulator Output Polarity Select bit

Modulator Output Polarity Select bit

ValueDescription
1

Modulator output signal is inverted; idle high output

0

Modulator output signal is not inverted; idle low output

Bit 0 – BIT: Modulation Source Select Input bit

Modulation Source Select Input bit

Allows software to manually set modulation source input to module