HLVDCON0

High/Low-Voltage Detect Control Register 0
Name:
HLVDCON0
Offset:
0xF2F
Reset:
Access:
Bit76543210
ENOUTRDYINTHINTL
AccessR/WROROR/WR/W
Reset0xx00

Bit 7 – EN: High/Low-voltage Detect Power Enable bit

High/Low-voltage Detect Power Enable bit

ValueDescription
1

Enables the HLVD module

0

Disables the HLVD module

Bit 5 – OUT: HLVD Comparator Output bit

HLVD Comparator Output bit

ValueDescription
1

Voltage ≤ selected detection limit (SEL)

0

Voltage ≥ selected detection limit (SEL)

Bit 4 – RDY: Band Gap Reference Voltages Stable Status Flag bit

Band Gap Reference Voltages Stable Status Flag bit

ValueDescription
1

Indicates HLVD Module is ready and output is stable

0

Indicates HLVD Module is not ready

Bit 1 – INTH: HLVD Positive going (High Voltage) Interrupt Enable

HLVD Positive going (High Voltage) Interrupt Enable

ValueDescription
1

HLVDIF will be set when voltage ≥ selected detection limit (SEL)

0

HLVDIF will not be set

Bit 0 – INTL: HLVD Negative going (Low Voltage) Interrupt Enable

HLVD Negative going (Low Voltage) Interrupt Enable

ValueDescription
1

HLVDIF will be set when voltage ≤ selected detection limit (SEL)

0

HLVDIF will not be set