Battery Backup Power Switch (BBPS) Control

Name:
BBPS
Offset:
0x20 [ID-00001e33]
Reset:
0x0000
Access:
PAC Write-Protection
Bit3130292827262524
Access
Reset
Bit2322212019181716
Access
Reset
Bit15141312111098
Access
Reset
Bit76543210
PSOKENWAKEENCONF[1:0]
AccessR/WR/WR/WR/W
Reset0000

Bit 3 – PSOKEN: Power Supply OK Enable

Power Supply OK Enable

ValueDescription
0

The PSOK pin is not used.

1 The PSOK pin is used to determine the status of the Main Power Supply.

Bit 2 – WAKEEN: Wake Enable

Wake Enable

ValueDescription
0 The device is not woken up when switched from battery backup power to Main Power.
1 The device is woken up when switched from battery backup power to Main Power.

Bits 1:0 – CONF[1:0]: Battery Backup Power Switch Configuration

Battery Backup Power Switch Configuration

ValueNameDescription
0x0 NONE The backup domain is always supplied by Main Power.
0x1 APWS The power switch is handled by the Automatic Power Switch.
0x2 FORCED The backup domain is always supplied by Battery Backup Power.
0x3 BOD33 The power switch is handled by the BOD33.