Status
Bit7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
EOC1 | EOC0 | READY1 | READY0 | ||||
Access | R | R | R | R | |||
Reset | 0 | 0 | 0 | 0 |
DAC1 End of Conversion
This bit is cleared when DATA1 register is written.
Value | Description |
---|---|
0 | No conversion completed since last load of DATA1. |
1 | DAC1 conversion is complete, VOUT1 is stable. |
DAC0 End of Conversion
This bit is cleared when DATA0 register is written.
Value | Description |
---|---|
0 | No conversion completed since last load of DATA0. |
1 | DAC0 conversion is complete, VOUT0 is stable. |
DAC1 Startup Ready
Value | Description |
---|---|
0 | DAC1 is not ready for conversion. |
1 | Startup time has elapsed, DAC1 is ready for conversion. |
DAC0 Startup Ready
Value | Description |
---|---|
0 | DAC0 is not ready for conversion. |
1 | Startup time has elapsed, DAC0 is ready for conversion. |