Event Control

Name:
EVCTRL
Offset:
0x03 [ID-0000120e]
Reset:
0x00
Access:
PAC Write-Protection, Enable-Protected
Bit76543210
WINMONEORESRDYEOSTARTINVFLUSHINVSTARTEIFLUSHEI
AccessR/WR/WR/WR/WR/WR/W
Reset000000

Bit 5 – WINMONEO: Window Monitor Event Out

Window Monitor Event Out

This bit indicates whether the Window Monitor event output is enabled or not and an output event will be generated when the window monitor detects something.

ValueDescription
0 Window Monitor event output is disabled and an event will not be generated.
1 Window Monitor event output is enabled and an event will be generated.

Bit 4 – RESRDYEO: Result Ready Event Out

Result Ready Event Out

This bit indicates whether the Result Ready event output is enabled or not and an output event will be generated when the conversion result is available.

ValueDescription
0 Result Ready event output is disabled and an event will not be generated.
1 Result Ready event output is enabled and an event will be generated.

Bit 3 – STARTINV: Start Conversion Event Invert Enable

Start Conversion Event Invert Enable

ValueDescription
0 Start event input source is not inverted.
1 Start event input source is inverted.

Bit 2 – FLUSHINV: Flush Event Invert Enable

Flush Event Invert Enable

ValueDescription
0 Flush event input source is not inverted.
1 Flush event input source is inverted.

Bit 1 – STARTEI: Start Conversion Event Input Enable

Start Conversion Event Input Enable

ValueDescription
0 A new conversion will not be triggered on any incoming event.
1 A new conversion will be triggered on any incoming event.

Bit 0 – FLUSHEI: Flush Event Input Enable

Flush Event Input Enable

ValueDescription
0 A flush and new conversion will not be triggered on any incoming event.
1 A flush and new conversion will be triggered on any incoming event.