Control Register E Set - Split Mode
Each Status bit can be read out either by reading TCA.CTRLESET or TCA.CTRLECLR.
Bit7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
CMD[1:0] | |||||||
Access | R/W | R/W | |||||
Reset | 0 | 0 |
Command
These bits are used for software control of update, restart, and reset of the timer/counter. The command bits are always read as zero.
Value | Name | Description |
---|---|---|
0x0 | NONE | No command |
0x1 | UPDATE | Force update |
0x2 | RESTART | Force restart |
0x3 | RESET | Force hard Reset (ignored if TC is enabled) |