Timer Counter Type D Configuration
The bit values of this fuse register are written to the corresponding bits in the TCD.FAULTCTRL register of TCD0 at start-up.

The CMPEN and CMP settings of the TCD will only be reloaded from the FUSE values after a Power-On Reset. For all other resets the corresponding TCD settings of the device will remain unchanged.

Name:
TCD0CFG
Offset:
0x04
Reset:
-
Access:
-
Bit76543210
CMPDENCMPCENCMPBENCMPAENCMPDCMPCCMPBCMPA
AccessRRRRRRRR
Reset00000000

Bits 4, 5, 6, 7 – CMPEN: Compare x Enable

Compare x Enable

ValueDescription
0 Compare x output on Pin is disabled
1 Compare x output on Pin is enabled

Bits 0, 1, 2, 3 – CMP: Compare x

Compare x

This bit selects the default state of Compare x after Reset, or when entering debug if FAULTDET is '1'.
ValueDescription
0 Compare x default state is 0
1 Compare x default state is 1