System and Reset Characteristics

Table 1. Reset, Brown-out and Internal Voltage Characteristics(1)
Symbol Parameter Condition Min. Typ Max Units
VPOT Power-on Reset Threshold Voltage (rising)   1.1 1.5 1.7 V
Power-on Reset Threshold Voltage (falling)(2)   0.6 1.0 1.7 V
SRON Power-on Slope Rate   0.01 - 9 V/ms
VRST RESET Pin Threshold Voltage   0.2 VCC - 0.9 VCC V
tRST Minimum pulse width on RESET Pin   - - 2.5 μs
VHYST Brown-out Detector Hysteresis   - 50 - mV
tBOD Min. Pulse Width on Brown-out Reset   - 2 - μs
VBG Bandgap reference voltage   1.0 1.1 1.2 V
tBG Bandgap reference start-up time VCC=2.7
TA=25°C - 40 70 μs
IBG Bandgap reference current consumption VCC=2.7
TA=25°C - 10 - μA
Note:
  1. Values are guidelines only.
  2. The Power-on Reset will not work unless the supply voltage has been below VPOT (falling)
Table 2. BODLEVEL Fuse Coding(1)(2)
BODLEVEL [2:0] Fuses Min. VBOT Typ. VBOT Max VBOT Units
111 BOD Disabled
110 1.7 1.8 2.0 V
101 2.5 2.7 2.9
100 4.1 4.3 4.5
011 - 000 Reserved
Note: VBOT may be below nominal minimum operating voltage for some devices. For devices where this is the case, the device is tested down to VCC = VBOT during the production test. This guarantees that a Brown-Out Reset will occur before VCC drops to a voltage where correct operation of the microcontroller is no longer guaranteed. The test is performed using BODLEVEL = 110, 101 and 100.
Note: VBOT tested at 25°C and 85°C in production